ICN 55 PLUS- Natural Incubator, capacity 55LT, with 7 programs x 10 ste ps
Features
Working range: +5°C Ta ... +70°C
Backlit LED display
Data download and recording via USB key
7 storable programmes with 10 steps each
Single-step basic programme
Multi-step programme with up to 64 steps
Other features
ArgoLab natural convection incubator.
Simultaneous display of all operating parameters.
Operator-silenced visual and acoustic alarms.
Digital timer 1 min - 99 h 59 min and continuous operation.
Delayed start' function of the heating cycle.
Safe temperature function: working temperature limitation for sample protection.
Minimum heating times and low heating power for low energy consumption in every application.
Working data logging of up to 200.000 values and download to USB stick.
Safety class 2 (DIN 12880).
Observation of samples without heat loss: door with large glass window (ICN 16 and ICN 35), double door (inside glass) in other models.
Passage hole Ø 5,5 mm as standard (upper side) for insertion of an external sensor for internal temperature control and/or certification.
Stainless steel chamber with rounded corners, fully removable anti-tip supports and shelves for easy cleaning.
Power supply 220 ± 10% V - 50/ 60 Hz.
Supplied as standard
steel grid shelves (n°2 shelves for models up to 55 liters, n°3 shelves for larger models), calibration report at 37°C carried out with Accredia-referenced sample instrument, USB stick for data recording and downloading.
Features
Working range: +5°C Ta ... +70°C
Backlit LED display
Data download and recording via USB key
7 storable programmes with 10 steps each
Single-step basic programme
Multi-step programme with up to 64 steps
Other features
ArgoLab natural convection incubator.
Simultaneous display of all operating parameters.
Operator-silenced visual and acoustic alarms.
Digital timer 1 min - 99 h 59 min and continuous operation.
Delayed start' function of the heating cycle.
Safe temperature function: working temperature limitation for sample protection.
Minimum heating times and low heating power for low energy consumption in every application.
Working data logging of up to 200.000 values and download to USB stick.
Safety class 2 (DIN 12880).
Observation of samples without heat loss: door with large glass window (ICN 16 and ICN 35), double door (inside glass) in other models.
Passage hole Ø 5,5 mm as standard (upper side) for insertion of an external sensor for internal temperature control and/or certification.
Stainless steel chamber with rounded corners, fully removable anti-tip supports and shelves for easy cleaning.
Power supply 220 ± 10% V - 50/ 60 Hz.
Supplied as standard
steel grid shelves (n°2 shelves for models up to 55 liters, n°3 shelves for larger models), calibration report at 37°C carried out with Accredia-referenced sample instrument, USB stick for data recording and downloading.
ICN 55 PLUS- Natural Incubator, capacity 55LT, with 7 programs x 10 ste ps
Features
Working range: +5°C Ta ... +70°C
Backlit LED display
Data download and recording via USB key
7 storable programmes with 10 steps each
Single-step basic programme
Multi-step programme with up to 64 steps
Other features
ArgoLab natural convection incubator.
Simultaneous display of all operating parameters.
Operator-silenced visual and acoustic alarms.
Digital timer 1 min - 99 h 59 min and continuous operation.
Delayed start' function of the heating cycle.
Safe temperature function: working temperature limitation for sample protection.
Minimum heating times and low heating power for low energy consumption in every application.
Working data logging of up to 200.000 values and download to USB stick.
Safety class 2 (DIN 12880).
Observation of samples without heat loss: door with large glass window (ICN 16 and ICN 35), double door (inside glass) in other models.
Passage hole Ø 5,5 mm as standard (upper side) for insertion of an external sensor for internal temperature control and/or certification.
Stainless steel chamber with rounded corners, fully removable anti-tip supports and shelves for easy cleaning.
Power supply 220 ± 10% V - 50/ 60 Hz.
Supplied as standard
steel grid shelves (n°2 shelves for models up to 55 liters, n°3 shelves for larger models), calibration report at 37°C carried out with Accredia-referenced sample instrument, USB stick for data recording and downloading.
Code: 41101022
Categories: Incubators
Caratteristiche | |
Capacity | |
Maximum shelf load | 10 |
Security class | 2 |
Dimension | |
Minimum distance between shelves | 50 |
Frequency | 50 - 60 |
Warranty | |
Working method | Natural convection |
Weight | 42 |
Absorbed power | 250 |
Programs | 7 programmes of 10 steps each and single step programme |
Temperature resolution | 0,1 |
Heating time (37°C) | 25 |
Timer | 99 : 59 |
Temperature variation at 37 °C | ±0,3 |
Useful volume | 55 |
Power supply | 230 |
Internal dimensions | 400 x 385 x 360 |
Overtemperature security | electronic |
Working temperature | +5 Ta…70 |
Display | LCD |
Regulations | 2006/95/EC -2004/108/EC - EN61326-1:2006 - EN61010-1:2010 - EN61010-2-010:2003 |
Number of shelves | 2 |
Temperature homogeneity at 37 °C | ±0,5 |
Packaging dimensions (W x D x H) |