ICF 120 PLUS- forced air Incubator, capacity 120 LT, with 7 programs x 10 steps
Features
Working range: +5°C Ta ... +80°C
Backlit LED display
Data download and recording via USB key
7 storable programmes with 10 steps each
Single-step basic programme
Multi-step programme with up to 64 steps
130°C sterilisation programme
Other features
ArgoLab forced ventilation incubator.
Simultaneous display of all operating parameters.
Operator-silenced visual and acoustic alarms.
Digital timer 1 min - 99 h 59 min and continuous operation.
Delayed start' function of the heating cycle.
Safe temperature' function: working temperature limitation for sample protection.
Special programme for sterilisation at 130°C.
Fan adjustable in 3 levels: High = 100% - Medium = 75% - Low = 50%.
Minimum heating times and low heating power for low energy consumption in every application.
Working data logging of up to 200.000 values and download to USB stick.
Safety class 3.1 (DIN 12880): maximum temperature controller with fluid expansion.
Observation of samples without heat loss: double door (glass interior).
Through-hole Ø 5 mm as standard (upper side) for insertion of an external sensor for internal temperature control and/or certification.
Stainless steel chamber with rounded corners, fully removable anti-tip supports and shelves for easy cleaning.
Door switch for easy sample loading and unloading.
Power supply 220 ± 10% V - 50/ 60 Hz.
Supplied as standard
steel grid shelves (n°2 for models up to 55 liters, n°3 for larger models), calibration report at 37°C performed with Accredia-referenced sample instrument, USB stick for data recording and downloading.
Features
Working range: +5°C Ta ... +80°C
Backlit LED display
Data download and recording via USB key
7 storable programmes with 10 steps each
Single-step basic programme
Multi-step programme with up to 64 steps
130°C sterilisation programme
Other features
ArgoLab forced ventilation incubator.
Simultaneous display of all operating parameters.
Operator-silenced visual and acoustic alarms.
Digital timer 1 min - 99 h 59 min and continuous operation.
Delayed start' function of the heating cycle.
Safe temperature' function: working temperature limitation for sample protection.
Special programme for sterilisation at 130°C.
Fan adjustable in 3 levels: High = 100% - Medium = 75% - Low = 50%.
Minimum heating times and low heating power for low energy consumption in every application.
Working data logging of up to 200.000 values and download to USB stick.
Safety class 3.1 (DIN 12880): maximum temperature controller with fluid expansion.
Observation of samples without heat loss: double door (glass interior).
Through-hole Ø 5 mm as standard (upper side) for insertion of an external sensor for internal temperature control and/or certification.
Stainless steel chamber with rounded corners, fully removable anti-tip supports and shelves for easy cleaning.
Door switch for easy sample loading and unloading.
Power supply 220 ± 10% V - 50/ 60 Hz.
Supplied as standard
steel grid shelves (n°2 for models up to 55 liters, n°3 for larger models), calibration report at 37°C performed with Accredia-referenced sample instrument, USB stick for data recording and downloading.
ICF 120 PLUS- forced air Incubator, capacity 120 LT, with 7 programs x 10 steps
Features
Working range: +5°C Ta ... +80°C
Backlit LED display
Data download and recording via USB key
7 storable programmes with 10 steps each
Single-step basic programme
Multi-step programme with up to 64 steps
130°C sterilisation programme
Other features
ArgoLab forced ventilation incubator.
Simultaneous display of all operating parameters.
Operator-silenced visual and acoustic alarms.
Digital timer 1 min - 99 h 59 min and continuous operation.
Delayed start' function of the heating cycle.
Safe temperature' function: working temperature limitation for sample protection.
Special programme for sterilisation at 130°C.
Fan adjustable in 3 levels: High = 100% - Medium = 75% - Low = 50%.
Minimum heating times and low heating power for low energy consumption in every application.
Working data logging of up to 200.000 values and download to USB stick.
Safety class 3.1 (DIN 12880): maximum temperature controller with fluid expansion.
Observation of samples without heat loss: double door (glass interior).
Through-hole Ø 5 mm as standard (upper side) for insertion of an external sensor for internal temperature control and/or certification.
Stainless steel chamber with rounded corners, fully removable anti-tip supports and shelves for easy cleaning.
Door switch for easy sample loading and unloading.
Power supply 220 ± 10% V - 50/ 60 Hz.
Supplied as standard
steel grid shelves (n°2 for models up to 55 liters, n°3 for larger models), calibration report at 37°C performed with Accredia-referenced sample instrument, USB stick for data recording and downloading.
Code: 41100812
Categories: Incubators
Caratteristiche | |
Capacity | |
Maximum shelf load | 20 |
Security class | 3.1 |
Dimension | |
Minimum distance between shelves | 50 |
Frequency | 50 - 60 |
Warranty | |
Working method | Forced ventilation |
Weight | 74 |
Absorbed power | 600 |
Programs | 7 programmes of 10 steps each and single step programme |
Temperature resolution | 0.1 |
Heating time (37°C) | 40 |
Timer | 99 : 59 |
Ventilation | At 3 speeds (50 %, 75 %, 100 %) |
Temperature variation at 37 °C | ±0,1 |
Useful volume | 120 |
Power supply | 230 |
Internal dimensions | 520 x 435 x 530 |
Overtemperature security | Electronic and electromechanical |
Working temperature | +5 Ta…80 |
Display | LCD |
Regulations | 2006/95/EC -2004/108/EC - EN61326-1:2006 - EN61010-1:2010 - EN61010-2-010:2003 |
Number of shelves | 3 |
Temperature homogeneity at 37 °C | ±0,4 |
Packaging dimensions (W x D x H) | |
Chamber sterilisation cycle | Yes, at 130°C |