Benvenuti in Giorgio Bormac S.r.l.

cambio lingua cambio lingua
https://app.onpage.it/api/storage/c671aa5fc26ea93f47430cd39d42b60aa431feb8.1800x.png/50014293.png

XS Tester PC 6 - KIT UN1760 LIQUIDO CORROSIVO, N.A.S. (acido cloridrico), 8, III, (E) / UN1760 CORROSIVE LIQUID, N.O.S. (hydrochloric acid), 8, III, (E)

Features

pH - Redox - Conductivity - TDS - Salinity

Other features

IP67 watertight portable multiparameter meter for pH, ORP, Conductivity, TDS and Salinity measurement.

With highly durable interchangeable combined electrode. Large 3-colour LCD display

with indication of buffers used for calibration and measurement stability. Automatic reading and

automatic temperature compensation (0...60 °C). Auto power-off.

Self-diagnosis messages: dead batteries, calibration errors.

Power supply 2 x 1.5V AAA batteries included, compatible with rechargeable batteries.

1-year warranty on electronics

pH: 0.01 pH resolution. Automatic 3-point calibration with 5 US buffer values and

oRP calibration on 1 user-defined point. MV reading for pH electrode diagnosis and for

oRP/Redox measurement.

COND: Automatic 3-point calibration with a choice of 3 standard values of 84 μS, 1413 μS and 12.88 mS. Automatic temperature compensation with TR= 20/25°C and adjustable coefficient

TC= 0.00...4.00%/°C.

TDS: TDS factor: 0.40...1.00.

Measuring range

pH: -2.00 ... 16.00 (0.01 pH)

mV: -1000 ... 1900

Cond: 0.01 μS ... 200 mS

TDS: 0.01 ppm ... 199.9 ppt

Salinity: 0.1 mg/l ... 100.0 g/l

°C: 0.0...60.0°C (0.1 °C)

Supplied as standard

buffer solutions pH 7 and pH 4 in 25 ml sachets, storage solution in sachet, 1 x 55 ml Redox solution 475 mV, standard solution 1413 μS in 25 ml sachet, calibration cap, strap, tissues, instructions and cardboard case.

XS Tester PC 6 - KIT UN1760 LIQUIDO CORROSIVO, N.A.S. (acido cloridrico), 8, III, (E) / UN1760 CORROSIVE LIQUID, N.O.S. (hydrochloric acid), 8, III, (E)

Features

pH - Redox - Conductivity - TDS - Salinity

Other features

IP67 watertight portable multiparameter meter for pH, ORP, Conductivity, TDS and Salinity measurement.

With highly durable interchangeable combined electrode. Large 3-colour LCD display

with indication of buffers used for calibration and measurement stability. Automatic reading and

automatic temperature compensation (0...60 °C). Auto power-off.

Self-diagnosis messages: dead batteries, calibration errors.

Power supply 2 x 1.5V AAA batteries included, compatible with rechargeable batteries.

1-year warranty on electronics

pH: 0.01 pH resolution. Automatic 3-point calibration with 5 US buffer values and

oRP calibration on 1 user-defined point. MV reading for pH electrode diagnosis and for

oRP/Redox measurement.

COND: Automatic 3-point calibration with a choice of 3 standard values of 84 μS, 1413 μS and 12.88 mS. Automatic temperature compensation with TR= 20/25°C and adjustable coefficient

TC= 0.00...4.00%/°C.

TDS: TDS factor: 0.40...1.00.

Measuring range

pH: -2.00 ... 16.00 (0.01 pH)

mV: -1000 ... 1900

Cond: 0.01 μS ... 200 mS

TDS: 0.01 ppm ... 199.9 ppt

Salinity: 0.1 mg/l ... 100.0 g/l

°C: 0.0...60.0°C (0.1 °C)

Supplied as standard

buffer solutions pH 7 and pH 4 in 25 ml sachets, storage solution in sachet, 1 x 55 ml Redox solution 475 mV, standard solution 1413 μS in 25 ml sachet, calibration cap, strap, tissues, instructions and cardboard case.

Code: 50014293

Categories: Multiparameter

Caratteristiche
Accuracy (pH) ±0,01
Accuracy (Temperature) ±0,5
Temperature coefficent (max) 0.00 … 4.00
Temperature compensation Yes
Dimension
Battery life > 200
TDS factor 0.40 … 1.00
Parameters pH - mV - ORP - Cond - TDS - SAL - T
Weight 0.11
Measuring range mV -1000 … +1000
mV ORP measuring range -1000 … +1000
PH calibration points 1 ... 3
pH measuring range -2,00 … 16,00
Salinity measuring range 0,01 mg/l … 100,0 g/l
Cond resolution Scala automatica
ORP resolution 0.1 / 1 (automatic scale)
pH resolution 0.01
Temperature resolution 0.1
Power supply 2 x AAA batteries 1.5
Accuracy (TDS) ±2 % f. s.
IP rating 67
Stability indication Yes
Auto off After 8 minutes
Replaceable sensor Yes
Recognised pH buffers 5 US pads
Swabs recognised Cond 84 µS / 1413 µS / 12,88 mS
Reference temperature 20,0 … 25,0
Accuracy (Cond) ±2 % f. s.
Temperature compensation (auto - manual) Automatic
Display 3-colour backlit LCD
Regulations CE
Calibration points Cond 1 ... 3
ORP calibration points 1 user-defined
Cond measuring range 0,01 µS … 199,9 mS
TDS measuring range 0,01 ppm … 199,9 ppt
temperature measurement range 0,0 … +60,0

Richiedi maggiori informazioni per questo prodotto.