Benvenuti in Giorgio Bormac S.r.l.

cambio lingua cambio lingua
https://app.onpage.it/api/storage/e20f7f50267a085264a1151a96dffd98b8812f81.1800x.png/50101212.png

XS pH 8 PRO Basic - Bench pHmeter - without electrode

Features

Resolution 0.1 / 0.01 / 0.001 pH

Backlit color graphic display

Manual or automatic temperature compensation

Manual and automatic data logger, up to 1000 GLP data

Numeric password

Other features

digital benchtop pH meter.

Automatic pH calibration on different buffer families, or manual (5 values).

Automatic and manual 1-point ORP calibration.

Recall and printout of calibration data.

Graphic display of electrode condition.

Calibration deadline warning and/or measurement block.

Alarm setting and display functions in analogue format, "Stop-reading" and "Stability" with titration mode (Tit) and time stability for ISE, self-diagnosis messages.

Numeric password for protection of saved data and calibration management.

Data logger for up to 1000 data in GLP.

Multilingual menu (Ita - Eng - Deu - Fra - Esp - Por).

Free Data-Link+ software at www.giorgiobormac.com for PC data management.

USB output for PC connection and RS232 port for printer connection.

Independently controlled magnetic stirrer (optional).

Measuring range

pH: -2,000...16,000 (0.001 pH)

mV: -2000...+2000 (0.1/1 mV)

ORP: -2000...+2000 (0.1/1 mV)

Temperature:-10...120.0 °C (0.1 °C)

Supplied as standard

S7/BNC cable, NT 55 temperature probe, stand
electrode holder, coloured buffer solutions, cable
USB cable and multi-socket power supply.

XS pH 8 PRO Basic - Bench pHmeter - without electrode

Features

Resolution 0.1 / 0.01 / 0.001 pH

Backlit color graphic display

Manual or automatic temperature compensation

Manual and automatic data logger, up to 1000 GLP data

Numeric password

Other features

digital benchtop pH meter.

Automatic pH calibration on different buffer families, or manual (5 values).

Automatic and manual 1-point ORP calibration.

Recall and printout of calibration data.

Graphic display of electrode condition.

Calibration deadline warning and/or measurement block.

Alarm setting and display functions in analogue format, "Stop-reading" and "Stability" with titration mode (Tit) and time stability for ISE, self-diagnosis messages.

Numeric password for protection of saved data and calibration management.

Data logger for up to 1000 data in GLP.

Multilingual menu (Ita - Eng - Deu - Fra - Esp - Por).

Free Data-Link+ software at www.giorgiobormac.com for PC data management.

USB output for PC connection and RS232 port for printer connection.

Independently controlled magnetic stirrer (optional).

Measuring range

pH: -2,000...16,000 (0.001 pH)

mV: -2000...+2000 (0.1/1 mV)

ORP: -2000...+2000 (0.1/1 mV)

Temperature:-10...120.0 °C (0.1 °C)

Supplied as standard

S7/BNC cable, NT 55 temperature probe, stand electrode holder, coloured buffer solutions, cable USB cable and multi-socket power supply.

Code: 50101212

Categories: Benchtop pHmeters

Caratteristiche
Accuracy (pH) ±0,002
Accuracy (Temperature) ±0,2
Magnetic stirrer
AQA calibration Yes
DHS compatibility Yes
Temperature compensation 0,0 ... +100,0
PC Communication USB type B
Printer connection
Stirring speed control
Criteria for stability of the measure Med - High - Tit
Dimension
Frequency 50 - 60
Warranty
AQA Yes
Inputs BNC - RCA
Selectable languages Eng - Ita - Deu - Esp - Fra - Por
Memory / Datalogger 1000
Parameters pH - mV - ORP - T
Password Yes, 8 numeric characters
Weight 0,709
Measuring range mV -2000 ... +2000
mV ORP measuring range -2000 ... +2000
PH calibration points 1 ... 5 automatic values - 2 user values
pH measuring range -2,000 ... +16,000
ORP resolution 0.1 / 1 (automatic)
pH resolution 0,1 / 0,01 / 0,001
Temperature resolution 0,1
Buzzer Yes
Timer calibration due with alarm Si
Stirring speed
Max stirring quantity
Power supply 100 - 240
Analog view Yes
IP rating 54
pH alarm range Min - Max
Recognised pH buffers USA - NIST - DIN 19266
Working temperature 0 ... +45
Temperature compensation (auto - manual) Yes
Display 4.3" high-definition, backlit colour TFT
Calibration data indication Yes with reports
Buffer used indication Yes with icon
Electrode status indication Yes with graph
ORP calibration points 1 automatic value - 1 user value
temperature measurement range -20,0 ... +120,0
Calibration Report Yes, printable
ORP alarm thresholds Min - Max
Data storage modes Manual - Automatic

Richiedi maggiori informazioni per questo prodotto.