XS Cond 60 VioLab Bench conductivity meter - Cell 2301 T
Features
Resolution 0,01 μS
Manual or automatic temperature compensation
Manual and automatic data logger, up to 1000 data in GLP
High-resolution, backlit color LCD display
Other features
Professional benchtop conductivity meter with innovative high-definition color LCD display with brightness adjustment capability.
Measurement of Conductivity, TDS, Salinity with temperature display.
Ability to select the parameters you want to see on the display.
Online help in setup and calibration allows easy and immediate use of the device.
Automatic calibration of conductivity (84 μS - 1413 μS -12.88 mS - 111.8 mS) and a user-defined point.
Automatic scale change, selectable reference temperature (15...30 °C) and selectable cell constant (C= 0,1 - 1 - 10).
Indication with icons of calibrated values.
Measurement stability indicator.
AQA functions: date and time, calibration data display and calibration deadline setting.
Manual and automatic data logger with possibility of data download to PC via micro-USB.
Connection to external printer via RS232 connector.
Data-Link software can be downloaded free of charge from www.giorgiobormac.com.
All operations are constantly monitored and reported to the operator via the colored LED above the display and self-diagnostic messages.
Measuring range
Cond: 0,0 μS ...200,00 mS (0,01 μS - automatic)
Salinity: 0,1 ppm...100 ppt
TDS: 0,01 mg/l...200 g/l
Temperature: - 10...+110,0 (0,1 °C)
Supplied as standard
Electrode holder stand, conductivity standard, USB cable, multi-socket power supply and instruction manual.
Features
Resolution 0,01 μS
Manual or automatic temperature compensation
Manual and automatic data logger, up to 1000 data in GLP
High-resolution, backlit color LCD display
Other features
Professional benchtop conductivity meter with innovative high-definition color LCD display with brightness adjustment capability.
Measurement of Conductivity, TDS, Salinity with temperature display.
Ability to select the parameters you want to see on the display.
Online help in setup and calibration allows easy and immediate use of the device.
Automatic calibration of conductivity (84 μS - 1413 μS -12.88 mS - 111.8 mS) and a user-defined point.
Automatic scale change, selectable reference temperature (15...30 °C) and selectable cell constant (C= 0,1 - 1 - 10).
Indication with icons of calibrated values.
Measurement stability indicator.
AQA functions: date and time, calibration data display and calibration deadline setting.
Manual and automatic data logger with possibility of data download to PC via micro-USB.
Connection to external printer via RS232 connector.
Data-Link software can be downloaded free of charge from www.giorgiobormac.com.
All operations are constantly monitored and reported to the operator via the colored LED above the display and self-diagnostic messages.
Measuring range
Cond: 0,0 μS ...200,00 mS (0,01 μS - automatic)
Salinity: 0,1 ppm...100 ppt
TDS: 0,01 mg/l...200 g/l
Temperature: - 10...+110,0 (0,1 °C)
Supplied as standard
Electrode holder stand, conductivity standard, USB cable, multi-socket power supply and instruction manual.
XS Cond 60 VioLab Bench conductivity meter - Cell 2301 T
Features
Resolution 0,01 μS
Manual or automatic temperature compensation
Manual and automatic data logger, up to 1000 data in GLP
High-resolution, backlit color LCD display
Other features
Professional benchtop conductivity meter with innovative high-definition color LCD display with brightness adjustment capability.
Measurement of Conductivity, TDS, Salinity with temperature display.
Ability to select the parameters you want to see on the display.
Online help in setup and calibration allows easy and immediate use of the device.
Automatic calibration of conductivity (84 μS - 1413 μS -12.88 mS - 111.8 mS) and a user-defined point.
Automatic scale change, selectable reference temperature (15...30 °C) and selectable cell constant (C= 0,1 - 1 - 10).
Indication with icons of calibrated values.
Measurement stability indicator.
AQA functions: date and time, calibration data display and calibration deadline setting.
Manual and automatic data logger with possibility of data download to PC via micro-USB.
Connection to external printer via RS232 connector.
Data-Link software can be downloaded free of charge from www.giorgiobormac.com.
All operations are constantly monitored and reported to the operator via the colored LED above the display and self-diagnostic messages.
Measuring range
Cond: 0,0 μS ...200,00 mS (0,01 μS - automatic)
Salinity: 0,1 ppm...100 ppt
TDS: 0,01 mg/l...200 g/l
Temperature: - 10...+110,0 (0,1 °C)
Supplied as standard
Electrode holder stand, conductivity standard, USB cable, multi-socket power supply and instruction manual.
Code: 50103072
Categories: Benchtop conductivity meters
Caratteristiche | |
Accuracy (Temperature) | ±0.5 |
Temperature coefficent (max) | 0,00 ... 10,00 |
Temperature compensation | 0,0 ... +100,0 |
PC Communication | Micro USB |
Printer connection | |
Dimension | |
TDS factor | 0.40 ... 1.00 |
Stability filter | 3 levels |
Warranty | |
AQA | Yes |
Inputs | BNC - RCA |
Memory | 1000 |
Output | Micro USB - RS 232 |
Weight | 0.38 |
Salinity measuring range | 0,1 ppm ... 100 ppt |
Cond resolution | 0,01 |
Temperature resolution | 0.1 |
Calibration due with alarm | Yes |
Power supply | 100 - 240 |
IP rating | 54 |
Online help | Yes |
Working temperature | 0 ... +45 |
Reference temperature | +15 ... +30 |
Accuracy (Cond) | ±2 % f.s. |
Display | High-definition, backlit colour LCD |
Buffer used indication | Yes with icon |
Calibration points Cond | 1 ... 4 |
Cond measuring range | 0.00 µS ... 200 mS |
TDS measuring range | 0.1 mg/l ... 200 g/l |
temperature measurement range | 0.0 ... 100.0 |
Calibration Report | Yes, printable |