Benvenuti in Giorgio Bormac S.r.l.

cambio lingua cambio lingua
https://app.onpage.it/api/storage/46f517a171712244a09af951ec286fd4d75c6947.1800x.png/41100912.png

ICF 120 SUPER - forced air Incubator, capacity 120 LT, with touch scree n

Features

Working range: +5°C Ta ... +80°C

4-inch colour touchscreen display

8 storable programmes with 8 steps each

Single-step basic programme

Multi-step programme with up to 64 steps

Data logging and downloading via USB key

Alarm and operation logging

Temperature ramps and graphic display

130°C sterilisation programme

Other features

ArgoLab forced ventilation incubator.

Simultaneous display of all operating parameters.

Operator-silenced visual and acoustic alarms.

Digital timer 1 min - 99 h 59 min and continuous operation.

Delayed start' function of the heating cycle.

Safe temperature' function: working temperature limitation for sample protection.

Special programme for sterilisation at 130°C.

Fan adjustable in 3 levels: High = 100% - Medium = 75% - Low = 50%.

Minimum heating times and low heating power for low energy consumption in every application.

Working data logging of up to 200.000 values and download to USB stick.

Alarm and operation logging.

Temperature ramp function for specialised applications.

Graphical display of temperature trends.

Multi-user management with 3 authorisation levels.

Safety class 3.1 (DIN 12880): maximum temperature controller with fluid expansion.

Observation of samples without heat loss: double door (glass interior).

Through-hole Ø 5 mm as standard (upper side) for insertion of an external sensor for internal temperature control and/or certification.

Stainless steel chamber with rounded corners, fully removable anti-tip supports and shelves for easy cleaning.

Door switch for easy sample loading and unloading.

Power supply 220 ± 10% V - 50/ 60 Hz.

Supplied as standard

steel grid shelves (n°2 for models up to 55 liters, n°3 for larger models), calibration report at 37°C performed with Accredia-referenced sample instrument, USB stick for data recording and downloading.

ICF 120 SUPER - forced air Incubator, capacity 120 LT, with touch scree n

Features

Working range: +5°C Ta ... +80°C

4-inch colour touchscreen display

8 storable programmes with 8 steps each

Single-step basic programme

Multi-step programme with up to 64 steps

Data logging and downloading via USB key

Alarm and operation logging

Temperature ramps and graphic display

130°C sterilisation programme

Other features

ArgoLab forced ventilation incubator.

Simultaneous display of all operating parameters.

Operator-silenced visual and acoustic alarms.

Digital timer 1 min - 99 h 59 min and continuous operation.

Delayed start' function of the heating cycle.

Safe temperature' function: working temperature limitation for sample protection.

Special programme for sterilisation at 130°C.

Fan adjustable in 3 levels: High = 100% - Medium = 75% - Low = 50%.

Minimum heating times and low heating power for low energy consumption in every application.

Working data logging of up to 200.000 values and download to USB stick.

Alarm and operation logging.

Temperature ramp function for specialised applications.

Graphical display of temperature trends.

Multi-user management with 3 authorisation levels.

Safety class 3.1 (DIN 12880): maximum temperature controller with fluid expansion.

Observation of samples without heat loss: double door (glass interior).

Through-hole Ø 5 mm as standard (upper side) for insertion of an external sensor for internal temperature control and/or certification.

Stainless steel chamber with rounded corners, fully removable anti-tip supports and shelves for easy cleaning.

Door switch for easy sample loading and unloading.

Power supply 220 ± 10% V - 50/ 60 Hz.

Supplied as standard

steel grid shelves (n°2 for models up to 55 liters, n°3 for larger models), calibration report at 37°C performed with Accredia-referenced sample instrument, USB stick for data recording and downloading.

Code: 41100912

Categories: Incubators

Caratteristiche
Capacity
Maximum shelf load 20
Security class 3.1
Dimension
Minimum distance between shelves 50
Frequency 50 - 60
Warranty
Working method Forced ventilation
Weight 74
Absorbed power 600
Programs 8 programmes of 8 steps each and single step programme
Temperature resolution 0.1
Data transfer YES, via USB stick
Heating time (37°C) 40
Timer 99 : 59
Ventilation At 3 speeds (50 %, 75 %, 100 %)
Temperature variation at 37 °C ±0,1
Useful volume 120
Power supply 230
Internal dimensions 520 x 435 x 530
Overtemperature security Electronic and electromechanical
Working temperature +5 Ta…80
Display Touch screen
Regulations 2006/95/EC -2004/108/EC - EN61326-1:2006 - EN61010-1:2010 - EN61010-2-010:2003
Number of shelves 3
Temperature homogeneity at 37 °C ±0,4
Packaging dimensions (W x D x H)
Chamber sterilisation cycle Yes, at 130°C

Richiedi maggiori informazioni per questo prodotto.